S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_gen_bse_pich.fm
Configuring the F-Pilot Channel (Forward PICH)
Configuring the F-Pilot Channel (Forward PICH)
The F-Pilot parameters are configured using the following call processing subsystem functions and commands.
Settable F-Pilot Parameters
F-Pilot level.
F-Pilot state.
PN Offset
Fixed F-Pilot Parameters
F-Pilot Walsh code is fixed at code channel number 0.
GPIB Examples:
Setting the F-Pilot Level
OUTPUT 714;"CALL:PIL -8 DB"
would set the F-Pilot state on and set the level to 8 dB. See CALL:PILOT[:SLEVel][:SELected] .
Querying the F-Pilot Level
OUTPUT 714;"CALL:PIL:LEVel?"
would query the last setting that was made to the F-Pilot level. See CALL:PILOT:LEVel[:SELected] .
Operating Considerations
The Walsh code number for the F-Pilot channel is fixed at code 0 of the Walsh 64 set.
Related Topics
CALL:PILot
How Do I Change Code Channel Levels?

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals