S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_pilot.fm
CALL:PILot
CALL:PILOT:LEVel[:SELected]
CALL:PILOT:STATe[:SELected]
Function Sets/queries the forward pilot channel (PICH) level.
The optional [:SELected] keyword in this command specifies that the pilot level being set/queried
applies to the current system type. See CALL[:CELL]:SYSTem[:TYPE] to query or change the
current system type.
Setting Range: 0 to -10 dB
Resolution: 0.01 dB
Query Range: 0 to -10 dB
Resolution: 0.01 dB
*RST Setting -7 dB
Programming Example
OUTPUT 714;"CALL:PILOT:LEVEL -10"
Function Sets/queries the forward pilot channel (PICH) state.
The optional [:SELected] keyword in this command specifies that the pilot state being set/queried
applies to the current system type. See CALL[:CELL]:SYSTem[:TYPE] to query or change the
current system type.
Setting Range: 1|ON|0|OFF
Query Range: 1|0
*RST Setting 1 (on)
Programming Example
OUTPUT 714;"CALL:PILOT:STATE OFF"