101
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_gen_bse_sync.fm
Configuring the F-Sync Channel (Forward SYNC)
Configuring the F-Sync Channel (Forward SYNC)
The F-Sync channel parameters are configured using the following call processing subsystem functions and
commands.
Settable F-Sync Parameters
F-Sync level.
F-Sync state.
Fixed F-Sync Parameters
The F-Sync Walsh code is fixed at code channel number 32.
GPIB Examples:
Setting the F-Sync state and level (complex command)
OUTPUT 714;"CALL:SYNC -16 DB"
would set the F-Sync state on and set the level to 16 dB. See CALL:SYNC[:SLEVel][:SELected] .
Querying the F-Sync Level
OUTPUT 714;"CALL:SYNC:LEVel?"
would query the last setting that was made to the F-PICH level. See CALL:PILOT:LEVel[:SELected] .