S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_prog_cpow.fm
Programming a Channel Power Measurement
830 ENTER A;Integrity,Channel_power
840 DISP "Test complete"
850 !
860 !***Display measurement results
870 PRINT "Integrity indicator = ";Integrity
880 PRINT "Minimum power = ";Channel_power;" dBm/1.23 MHz"
890 !
900 !***Return to default call processing states***
910 OUTPUT A;"CALL:CLPCONTROL:REVERSE:MODE ACTIVE" !Returns to active power control bits
920 OUTPUT A;"CALL:CONNECTED:DROP:TIMER:STATE 1" !Returns call drop timer to ON
930 OUTPUT A;"CALL:REGISTER:TIMER:STATE ON" !Returns timer-based registration to ON
940 OUTPUT A;"CALL:POW -50" ! Returns cell power to -50 dBm/1.23 MHz
950 !
960 DISP "Test complete"
970 OUTPUT A;"CALL:END" !Ends the call
980 END
990 Timeout: SUB Timeout ! Global timeout handler
1000 PRINT "Program timed out"
1010 CLEAR 7
1020 CLEAR 714
1030 SUBEND
Returned Values
This query returns an integrity indicator followed by a channel power measurement result (if results are available).
Related Topics
Channel Power Measurement Description on page 44
Channel Power Measurement Troubleshooting on page 706
CALibration Subsystem on page 259

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals