EasyManuals Logo

Agilent Technologies 8960 Series Reference Guide

Agilent Technologies 8960 Series
786 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
94
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_gen_bse_pch.fm
Configuring the F-Paging Channel (F-PCH)
Configuring the F-Paging Channel (F-PCH)
The F-Paging channel parameters are configured using the following call processing subsystem functions and
commands.
Settable F-Paging Parameters
F-Paging level.
F-Paging state.
F-Paging data rate.
F-Paging IMSI type.
F-Paging IMSI MCC (mobile country code).
F-Paging IMSI MNC (mobile network code).
F-Paging IMSI MSIN (mobile station identification number).
F-Paging maximum slot cycle index.
Fixed F-Paging Parameters
The F-Paging Walsh code is fixed at code channel number 1.
GPIB Examples:
Setting the F-Paging state and level (complex command)
OUTPUT 714;"CALL:PAG -12 DB"
would set the F-Paging state on and set the level to 12 dB. See CALL:PAGing[:SLEVel][:SELected] .
Setting the F-Paging data rate
OUTPUT 714;"CALL:PAGING:DRATE HALF"
would set the F-Paging data rate to half-rate. See CALL:PAGing:DRATe .

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals