EasyManuals Logo
Home>Agilent Technologies>Test Equipment>8960 Series

Agilent Technologies 8960 Series Reference Guide

Agilent Technologies 8960 Series
786 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #424 background imageLoading...
Page #424 background image
424
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_fetch_atxpower.fm
FETCh:ATXPower
FETCh:ATXPower
Diagram Conventions on page 248
FETCh:ATXPower[:ALL]?
Function Queries the average analog transmitter power measurement. The query returns integrity, and
average analog power.
Query Range: -100 dBm to +100 dBm
Resolution: 0.01 dB
Programming Example
OUTPUT 714;FETCH:ATXPOWER:ALL? !Returns integrity and average analog power.
FETCh :ATXPower
:ALL?
(returns Integrity,Avg Analog Power
:POWer
(returns Min Analog Power,
Std Dev Analog Power)
[:AVERage]
:MAXimum?
(returns Avg Analog Power)
(returns Max Analog Power)
:MINimum?
(returns Min Analog Power)
:SDEViation?
(returns Std Dev Analog Power)
:ICOunt?
(returns Intermediate Count)
?
(returns Integrity)
:INTegrity?
[:ALL]
?
Max Analog Power,Avg Analog Power,

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals