EasyManua.ls Logo

Agilent Technologies 8960 Series

Agilent Technologies 8960 Series
786 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
293
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_escape.fm
CALL[:CELL]:ESCape[:MODE]
CALL[:CELL]:ESCape[:MODE]
Diagram Conventions on page 248
CALL[:CELL]:ESCape[:MODE]
Function Sets/queries CDG escape mode. When escape mode is on, the test set is configured as a base
station that sends (in its overhead messages) all 1s in the messaging fields used to signal mobile
country code (MCC) and mobile network code (MNC). A mobile station that supports escape mode
will respond by assuming MCC/MNC compatibility and perform registrations using only the
mobile station identification number (MSIN).
Setting Range: 1|ON|0|OFF
Query Range: 0|1
*RST Setting 0 (off)
Programming Example
OUTPUT 714;"CALL:CELL:ESCAPE:MODE 1" !Sets CDG escape mode on.
:ESCapeCALL
[:CELL]
<sp>1|ON|0|OFF
? (returns 1|0)
[:MODE]

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Related product manuals