CALL[:CELL]:ESCape[:MODE]
CALL[:CELL]:ESCape[:MODE]
Diagram Conventions on page 248
CALL[:CELL]:ESCape[:MODE]
Function Sets/queries CDG escape mode. When escape mode is on, the test set is configured as a base
station that sends (in its overhead messages) all 1s in the messaging fields used to signal mobile
country code (MCC) and mobile network code (MNC). A mobile station that supports escape mode
will respond by assuming MCC/MNC compatibility and perform registrations using only the
mobile station identification number (MSIN).
Setting Range: 1|ON|0|OFF
Query Range: 0|1
*RST Setting 0 (off)
Programming Example
OUTPUT 714;"CALL:CELL:ESCAPE:MODE 1" !Sets CDG escape mode on.
:ESCapeCALL
[:CELL]
<sp>1|ON|0|OFF
? (returns 1|0)
[:MODE]