348
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_pilot.fm
CALL:PILot
CALL:PILot
Diagram Conventions on page 248
CALL:PILOT[:SLEVel][:SELected]
Function The setting form of this command performs two functions: (1) sets the PICH (forward pilot
channel) level, and (2) turns the PICH state to ON.
The query form returns the PICH level.
The optional [:SELected] keyword in this command specifies that the pilot channel state and
level being set/queried applies to the current system type. See CALL[:CELL]:SYSTem[:TYPE]
to query or change the current system type.
Setting Range: 0 to -10 dB
Resolution: 0.01 dB
Query Range: 0 to -10 dB
Resolution: 0.01 dB
*RST Setting -7 dBm
Programming Example
OUTPUT 714;"CALL:PILOT:SLEVel -10"
!Sets the cell pilot state to ON and sets the level to -10 dB.
<sp><num value>[DB]
? (returns num value)
CALL
<sp><num value>[DB]
[:SLEVel]
?(returns num value)
<sp>1|ON|0|OFF
:STATe
? (returns num value)
Complex Command
[:SELected]
:DIGital2000
[:SELected]
:DIGital2000
[:SELected]
:DIGital2000
:LEVel
:PILot
:DIGital95
:DIGital95
:DIGital95

Table of Contents