427
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_fetch_cappower.fm
FETCh:CAPPower
FETCh:CAPPower
“Diagram Conventions” on page 248
FETCh:CAPPower[:ALL]?
FETCh:CAPPower:INTegrity?
Function Queries the access probe power measurement results.
This query returns an integrity indicator followed by the most recent access probe power
measurement result (if results are available).
Query • Range: -100 to 100 dBm, 9.91 E+37
• Resolution: 0.01 dBm
Programming Example
OUTPUT 714;"FETCH:CAPPower:ALL?" !Returns integrity, access probe power measurement.
Function Queries the measurement integrity indicator for the last access probe power measurement
completed.
Zero indicates a normal measurement. See “Integrity Indicator” on page 222 for information
about non-zero integrity results.
Query Range: 0 through 23
Programming Example
OUTPUT 714;"FETCH:CAPPower:INTegrity?"
!Queries the integrity indicator for the most recent access probe power results.
FETCh :CAPPower (returns Integrity, Access Probe Power)
[:ALL]
?
(returns Integrity)
:INTegrity?