Page #328 background imageLoading...
Page #328 background image
328
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_ms_reported_m.fm
CALL:MS:REPorted:<MCC,MIN1,MIN2,MNC,MSIN>
CALL:MS:REPorted:MNCode?
CALL:MS:REPorted:MSINumber?
Function Queries the mobile network code (MNC), as reported by the mobile station.
Query Range: 0 to 999
*RST Setting Null string
Programming Example
OUTPUT 714;CALL:MS:REPORTED:MNCODE?
Function Queries the mobile station reported mobile station identification number.
Query Range: returns up to 10 digits
*RST Setting Null string
Programming Example
OUTPUT 714;CALL:MS:REPORTED:MSINUMBER?