Maintenance-Object Repair Procedures
555-233-143
8-290 Issue 1 May 2002
PASS The ATM-TRK circuit pack is successfully reset.
0NO
BOARD
No board detected.
1. Check the error log for Error 125 (wrong board) or Error 131 (no board),
and perform the appropriate repair, if needed.
2. Ensure that the board is properly translated and inserted.
3. Check for Error 1538 (hyperactivity). If hyperactive, run reset board
UUCSS.
4. Run the test again. If it fails, replace the ATM-TRK circuit pack, and retest.
Table 8-125. ATM Board Reset (#1256) — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page