Maintenance Commands
555-233-143
7-448 Issue 1 May 2002
test maintenance
test maintenance [C] [short | long] [repeat# | clear] [schedule]
NOTE:
This command is not valid for S8700 IP Connect configurations.
The test maintenance command performs hardware diagnostic tests on the PN’s
Maintenance circuit packs.
For a PN’s Maintenance circuit pack, the MT interface, EI link, reset, and sanity
functions are tested. The long test resets the PN’s Maintenance circuit pack,
causing a local login via the Maintenance board to drop.
The optional parameter
C specifies a cabinet. The cabinet number defaults to 1.
Output
The following display shows a typical result when test maintenance 2 is entered.
test maintenance 2
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
02A MAINT 106 PASS
02A MAINT 229 PASS
02A MAINT 303 PASS
02A MAINT 854 PASS
02A MAINT 337 PASS
Command successfully completed