Maintenance-Object Repair Procedures
555-233-143
8-42 Issue 1 May 2002
ALARM-PT (ALARM PORT)
The Alarm port MO provides on-board maintenance for an analog line port that is
administered as an external device alarm port. Tests are provided to verify the
analog line ports ability to detect an external device alarm. The external device
alarm (EXT-DEV) MO is used for the off-board external device alarm.
Error Log Entries and Test to Clear Values
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate errors.
b. Indicates that the circuit pack has been removed or has been insane for
more than 11 minutes. To clear the error, reseat or replace the circuit pack.
MO’s Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
pp is the 2-digit port number (01, 02,...).
Full Name of MO
ALARM-PT MINOR test port UUCSSpp l Alarm-Port
ALARM-PT WARNING test port UUCSSpp sh Alarm-Port
Table 8-16. 8-Port Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0Any Any Anytest port UUCSSpp sh r 1
15 (a) Any Audits and
Updates test
(#36)
18 0 busyout
station
extension
WARNING OFF release station extension
130 (b) None WARNING ON test port UUCSSpp sh
769 Battery Feed
test (#35)
MINIOR ON test port UUCSSpp sh r 2