INADS (INADS Link)
Issue 1 May 2002
8-925555-233-143
INADS (INADS Link)
The INADS Link MO represents the software and communications link used by
the switch to call an alarm receiver. The purpose of the INADS Link MO is to:
Check the communications link between the system and the alarm receiver
Verify that the alarm notification process works correctly
To verify that alarms will be reported to the alarm receiver, either a centralized
technician can remotely test the process, or an on-site technician can test the
connection either during an installation or a subsequent service call.
Although the INADS Link MO never alarms, its errors are logged, and these errors
are only logged by issuing the test inads-link command.
Error Log Entries and Test to Clear Values
The Hardware Error Log entries are described as part of the following INADS Link
test description.
System Technician-Demanded Tests:
Descriptions and Error Codes
The test inads-link command is different from other test commands in that the:
Command does not have a long or short option
Resulting test does not have an associated test number.
When a user issues the test inads-link command, the system immediately
returns either the Command successfully completed or Command failed
message.
MOs Name (in
Alarm Log) Alarm Level
Initial SAT Command to
Run Full Name of MO
INADS none test inads-link INADS Link