RANL-STA (Remote Analog Line (Station) Port
Issue 1 May 2002
8-1333555-233-143
RANL-STA (Remote Analog Line
(Station) Port
A per-port instance of this MO (RANL-STA) is used to maintain the circuitry
associated with a port which has been translated as analog station. The combo
blade circuit board has the capability of having two instances of this type of MO.
Failures of the neon message waiting lamp power and the common ringing
application circuitry are reported as part of common port circuit pack errors; see
errors 1281 and 1793 in ‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872.
Ringing Caused by Maintenance Testing
Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing disturbs the customer or the terminal equipment,
disable it in the Tests field of the change station extension form. Be aware that
this action will also disable Test 35 on that station.
MOs Name (in
Alarm Log) Alarm Level
Initial SAT Command to
Run
1
1. UU is the universal cabinet number (164 for ATM PNC, 144 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (0121).
pp is the 2-digit port number (01, 02,...).
Full Name of MO
RANL-STA MINOR test port UUCSSpp l Remote Analog Line
Port
RANL-STA WARNING test port UUCSSpp sh Remote Analog Line
Port