Maintenance Commands
555-233-143
7-432 Issue 1 May 2002
test environment
test environment UU [short | long] [repeat# | clear] [schedule]
The test environment command performs hardware diagnostic tests of the
environment monitoring and control, and emergency transfer functions of a
specified cabinet. This command tests EPN cabinets. Circuit packs involved are
the EPNs Maintenance and Tone-Clock (for the ring generator test).
!
CAUTION:
The long test recycles power on every port circuit pack carrier and is
destructive. It does not recycle power on active or standby EPN control or
switch node carriers. When a port carrier is recycled, all service and links to
ports on the carrier are dropped. If a carrier containing an active EI or
Tone-Clock is recycled, all service to that cabinet will be disrupted.
There are 10 Maintenance Objects involved in this test:
Note that although the CUST-ALARM maintenance object is part of the
environment functionality, it is not actually tested using the test maintenance
command. See test customer-alarm for details on testing this particular MO.
NOTE:
A new MO, RMC-ENV, displays when the rack mount cabinet is used for the
S8700 IP Connect.
EMG-XFER CABINET
AC-POWER RING-GEN
CARR-POW CUST-ALARM
POWER EXT-DEV
DC-POWER RMV-GEN