test sys-link
Issue 1 May 2002
7-457555-233-143
test sys-link
test sys-link UUCSSpp [channel# ] [current | faulted]
[short | long] [repeat# | clear] [schedule]
The test sys-link command will validate the existence of the specified link and
run diagnostic tests on the hardware path that comprises the system link. If the
current or faulted option is specified, tests are run on every hardware object
that comprises the specified link. If current or faulted is not specified, only the
end-to-end sys-link connection will be tested.
The hardware path that comprises a system link consists of up to 21 hardware
components that affect the behavior of the link. The number of components of a
given system link hardware path depends on the system configuration and type of
system link. The following links are examples of system links: EAL (Expansion
Archangel Link), INL (Indirect Neighbor Link), and PRI (PRI signaling link).
Parameters
Examples
test sys-link 2e0201 current l schedule
test sys-link 2e0201 faulted r 10
test sys-link 1c1701 channel 3 r 10
UUCSSpp The location of the port associated with the system link.
current This specifies testing of the current hardware path of the system link.
faulted This specifies testing of the hardware path of the system link as it was constituted
when a fault last caused the link to go down. For more information, see ‘‘Common
Input Parameters’’ at the beginning of this chapter.