Maintenance-Object Repair Procedures
555-233-1438-723 Issue 1 May 2002
8
E-DIG-BD (Multi Application
Platform Board)
The maintenance strategy for DIG800-BD is the same as the one described for
MO-COMBD (‘‘XXX-BD (Common Port Circuit Pack)’’). Maintenance testing of
the common circuit pack is handled by on-board firmware and server-controlled
tests. Maintenance software queries the firmware for error and alarm information,
status, and test results. The firmware automatically reports error conditions that
will result in server-controlled testing.
Board Insertion
The switch makes an additional board query if any of the following circuit packs
are inserted:
For any of the previous initial board up-links, the switch sends queries requesting
additional data from the board for administration purposes, while also telling the
board the switch software release and the system type.
For the native mode, the response to the board query downlink messages
consists of several CCMS uplink messages that identify the true board code,
vintage, suffix, emulation type, and the number of reserved slots it needs.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial SAT Command to
Run
1
1. Where UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC); C is the
carrier designation (A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit
pack resides (1 – 21); and pp is the 2-digit port number (01, 02, 03, ...).
Full Name of MO
DIG800-BD MINOR test board UUCSS sh MO800DIG-BD
DIG800-BD WARNING test board UUCSS sh MO800DIG-BD
Circuit Pack Vintage
TN754 49
TN556 49,
80 or greater