EasyManua.ls Logo

Avaya S8700 - ADX16 D-B (16-Port AUDIX Circuit Pack)

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance-Object Repair Procedures
555-233-143
8-24 Issue 1 May 2002
ADX16D-B (16-Port AUDIX Circuit
Pack)
The ADX16D-BD MO represents a TN566/TN2169 EMBEDDED AUDIX circuit
pack combination operating in 16-port mode digital (DP). For circuit-pack-level
problems, see ‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872. Port-level
maintenance is covered by ADX16D-PT.
EMBEDDED AUDIX consists of two circuit packs that occupy 5 slots on a port
carrier. The tests described in this manual apply only to switch-side maintenance
that tests a circuit packs components related to the TDM-bus interface. The
AUDIX system has an extensive maintenance strategy of its own that is described
in EMBEDDED AUDIX System Maintenance, 585-300-110.
MOs Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. UU is the universal cabinet number (164 for ATM PNC, 144 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (0121).
Full Name of MO
ADX16D-B MINOR test board UUCSS sh AUDIX circuit pack
ADX16D-B WARNING test board UUCSS sh AUDIX circuit pack