Maintenance Commands
555-233-143
7-114 Issue 1 May 2002
Output
Field Descriptions
Port
The physical location of the alarmed object. For circuit pack based MOs,
the location is cabinet-carrier-[slot]-[circuit]. For PN-based objects, such as
TDM-BUS, the location displays as 3PN xx, where xx is the PN number.
For Fiber Link-based objects, the location displays as
x a,b-PNC where
x is the Fiber Link number and a- or b-pnc indicates one of the PNC pair.
(Always a-pnc for a high-reliability system, with an unduplicated PNC.)
MaintenanceNam
e
The abbreviated name of the MO that encountered the error.
Alt Name
An alternate means of identifying the MO.
Error Type
Numerical error code that identifies the type of problem. The meanings of
these codes are explained under the name of the MO in Chapter 8.
Aux Data
Additional numerical information about the error type. Only the most recent
auxiliary data for each error type is displayed.
First Occur
Month, day, hour, and minute (and second, if the high-resolution
command-line option is used) that the error was first recorded.
display errors Page 1 of 1
ERROR REPORT
The following options control which errors will be displayed.
ERROR TYPES
Error Type: ____ Error List: active-alarms
REPORT PERIOD
Interval: _ From: __/__/__:__ To: __/__/__:__
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet: __
Port Network: __
Board Number: ____
Port: ______
Category: ________
Extension: _____
Trunk ( group/member ): __/__