Maintenance Commands
555-233-143
7-76 Issue 1 May 2002
change system-parameters
maintenance
This command specifies and displays scheduled maintenance operations and
maintenance support functions. It also activates and deactivates INADS alarm
origination during repairs. To deactivate alarm origination:
1. If daily scheduled maintenance must remain idle during a maintenance
procedure, set the
Start Time field to a time after the session ends. If
daily Scheduled Maintenance is running and needs to be deactivated, set
the
Stop Time field to one minute after the current time.
2. Press
Enter and verify that the screen displays the message:
Command successfully completed
NOTE:
When finished working on the switch, be sure to return every field to
its original setting.
Output (Page 1)
The following output example shows a display of page 1 of the change
system-parameters maintenance
command.
Table 7-11. change system-parameters maintenance command parameters
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
change
system-parameter
s maintenance
Examples:
change
system-parameters
maintenance
init
inads
craft
cust
rcust
none none
change system-parameters maintenance Page 1 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
SCHEDULED MAINTENANCE
Start Time: 01 : 00
Stop Time: 06 : 00
Save Translation: daily
Command Time-out (hours): 2
Control Channel Interchange: no
System Clocks/IPSI Interchange: no