PLAT-ALM (Platform Alarms)
Issue 1 May 2002
8-1269555-233-143
PLAT-ALM (Platform Alarms)
The PLAT-ALM is a virtual MO used by the S8700 Multi-Connects MultiVantage
software to keep track of its media server alarms. A MAJOR, MINOR, or
WARNING alarm can be logged against this MO to indicate the presence of one
or multiple S8700 media server alarms.
A technician who is using the SAT and finds an alarm against the PLAT-ALM MO
must:
1. Log into the media servers Linux shell.
2. To see the media servers current list of alarms, execute the almdisplay
command.
3. To clear the problems, follow the troubleshooting procedures listed there
for media server alarms.
NOTE:
After repairing the media server, use the Linux almclear command to
manually clear every media server alarm. This action will also clear any
alarms associated with the PLAT-ALM MO.
System Technician-Demanded Tests:
Descriptions and Error Codes
This MO provides no on-demand tests for system technicians.