Additional Maintenance Procedures
555-233-143
5-32 Issue 1 May 2002
Removing and Restoring Power
!
CAUTION:
If there is an alarm or problem suspected on the removable media do not
save translations to the affected device.
Removing and Restoring Power to the Media
Gateway:
1. For a multicarrier EPN cabinet, set the emergency transfer switch to ON.
This locks the EPN in the emergency transfer mode until the trouble is
cleared.
2. Depending on which type of cabinet you are powering down, do one of the
following:
In an AC-powered multicarrier cabinet, set the circuit breaker to OFF
at the power-distribution unit.
In a DC-powered multicarrier cabinet, turn off the DC power supply.
In an AC- or DC-powered single-carrier cabinet stack, turn off the
power for each affected carrier individually. The ON/OFF switch is
located behind the:
AC carriers WP-91153 power unit
DC carriers 676B power unit
3. Power is restored by reversing the action taken above.
Restoring power will cause a restart. This process is described under
EXP-PN in ‘‘ABRI-PORT (ASAI ISDN-BRI Port)’’ on page 8-3.
If a powered-down carrier contains a 676B power unit, the 676B must have
been powered down for at least 10 seconds for the unit to restart.