Maintenance-Object Repair Procedures
555-233-143
8-354 Issue 1 May 2002
BRI-SET, ASAI-ADJ, BRI-DAT
!
WARNING:
‘‘Isolating and Repairing Packet-Bus Faults’’ information for isolating and
resolving packet-bus faults is included in Chapter 4, ‘‘Alarms, Errors, and
Troubleshooting’’. The flowchart Figure 4-45, Troubleshooting Packet Bus
Problems along with the other information presented in the chapter, can help
resolve problems that involve more than a single station or circuit pack. See
also ‘‘Maintenance of the Packet Bus’’ on page 4-87
!
WARNING:
If a significant packet-bus failure occurs, errors and alarms may not be
logged as expected for BRI-PORT/ABRI-POR/ATT-PORT/ LGATE-PT/
ATTE-PT. Conditions under which this occurs are detailed in the
‘‘Maintenance of the Packet Bus’’ section of Chapter 4, ‘‘Alarms, Errors, and
Troubleshooting’’.
MOs Name As It
Appears in
Alarm Log Alarm Level Initial Command to Run
1
1. UU is the universal cabinet number (164 for ATM PNC, 144 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (0121). pp is the 2-digit port number
(01, 02,...).
Full Name of MO
BRI-SET
BRI-DAT
WARNING
2
2. The alarm level for ASAI and Avaya adjuncts may be administered using the set options command. The alarm
level can be set independently for on- and off-board alarms to WARNING, MINOR, or MAJOR for every ASAI
and Avaya adjunct in the system.
test station extension l
test data-module extension
ISDN-BRI Set
ASAI-ADJ MAJOR
2
) test station extension ASAI-Adjunct
ASAI-ADJ MAJOR
2
test data-module extension ASAI-Adjunct
ASAI-ADJ WARNING
3
3. Alarming for an ASAI and Avaya adjuncts is disabled if the adjunct asks the switch to suspend maintenance.
When this occurs, an error and a WARNING alarm are logged against the endpoint. Busying out and releasing
the ASAI station or ADJLK station will clear the alarm.
test data-module extension ASAI-Adjunct
ATT-ADJ MAJOR
2
test station extension Avaya-Adjunct
ATT-ADJ MAJOR
2
test station extension Avaya-Adjunct
ATT-ADJ WARNING
3
test station extension Avaya-Adjunct
LGATE-AJ MAJOR
2
test station extension Ethernet ASAI-Adjunct
LGATE-AJ MAJOR
2
test station extension Ethernet ASAI-Adjunct
LGATE-AJ WARNING
3
test station extension Ethernet ASAI-Adjunct
ATTE-AJ MAJOR
2
test station extension Ethernet Avaya-Adjunct
ATTE-AJ MAJOR
2
test station extension Ethernet Avaya-Adjunct
ATTE-AJ WARNING
3
test station extension Ethernet Avaya-Adjunct