CLSFY-PT (Call Classifier Port)
Issue 1 May 2002
8-429555-233-143
CLSFY-PT (Call Classifier Port)
The TN744 Call Classifier is a service circuit pack that provides specialized tone
detection capabilities to support the Outbound Call Management (OCM) and
Inbound Call Management (ICM) features. The TN744 supports both A-law and
Mu-law companding.
The TN744 has eight ports (CLSFY-PTs), each capable of supporting call
classification, touch-tone reception and MFC-tone generation and detection. The
CLSFY-PT MO implements a set of tests designed to ensure proper operation of
the Call Classifier.
Error Log Entries and Test to Clear Values
MO’s Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
pp is the 2-digit port number (01, 02, 03 ...).
Full Name of MO
CLSFY-PT
1
MAJOR test port UUCSSpp sh Call Classifier Port
CLSFY-PT MINOR test port UUCSSpp sh Call Classifier Port
CLSFY-PT WARNING test port UUCSSpp sh Call Classifier Port
Table 8-175. Call Classifier Port (CLSFY-PT) Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1 any Tone Detector
Audit/Update test (#43)
MAJOR/
MINOR(a)
ON test port UUCSSpp r 2
18 busyout port WARNING OFF release port
UUCSSpp
257(b) 17666 Tone Detection Audit
Update test (#43)
MAJOR/
MINOR(a)
ON test port UUCSSpp r 3
513(c) any Tone Detection Verification
test (#42)
MAJOR/
MINOR(a)
ON test port UUCSSpp r 3