Maintenance Commands
555-233-143
7-344 Issue 1 May 2002
status data-module
status data-module extension [print]
This command displays internal software states of a specified data-module port.
It is useful for diagnosis and locating facilities to which the data module is
connected.
Output
Field Descriptions
If the specified port is administered as a system port, the following fields will be
for more information.
Data Ext/Sta
Ext for Stn DM
The data modules extension number. For DTDMs, the connected station
extension is shown instead.
Port/ChannelNu
mber
The location of the port connected to the data module. For data channels, the
channel number is shown instead.
Service State
The operational state of the data-module:
in-service/idle The data module is connected but idle.
in-service/active The data module is connected and in use.
out-of-service The data module has been removed from service.
CF Destination Ext
The call-forwarding destination, if any, of the port.
Maintenance Busy
Whether the port is busied out for testing.
Connected Ports
Locations of ports to which the data module is currently connected.
Service State
The operational state of the associated port.
status data-module 70058
DATA-MODULE STATUS
Data Ext/Stn Ext for Stn DM: Service State: in-service/idle
Port/Channel Number: 26A0817 Maintenance Busy? no
CF Destination Ext:
Connected Ports: