ADX16A-BD (AUDIX Circuit Pack)
Issue 1 May 2002
8-25555-233-143
ADX16A-BD (AUDIX Circuit Pack)
The ADX16A-BD MO represents a TN566/TN2169 EMBEDDED AUDIX circuit
pack combination operating in control-link (CL) mode. For circuit-pack-level
problems, see ‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872. Port-level
maintenance is covered by ADX16A-PT.
EMBEDDED AUDIX consists of two circuit packs that occupy 5 slots on a port
carrier. The tests described in this manual apply only to switch-side maintenance
that tests a circuit pack’s components related to the TDM-bus interface. The
AUDIX system has an extensive maintenance strategy that is described in
EMBEDDED AUDIX System Maintenance, 585-300-110.
MO’s Name (in
Alarm Log) Alarm Level Initial Command to Run
1
1. UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
Full Name of MO
ADXCL-BD or
\ADX16A-BD
MINOR, or
WARNINGS
test board UUCSS sh AUDIX circuit pack