Maintenance-Object Repair Procedures
555-233-143
8-330 Issue 1 May 2002
BRI-PORT (ISDN-BRI Port),
ABRI-PORT (ASAI ISDN-BRI Port)
NOTE:
Some of the information in this section is reserved for future use.
!
CAUTION:
The section, ‘‘Isolating and Repairing Packet-Bus Faults’’ on page 4-81, is
included in Chapter 4, ‘‘Alarms, Errors, and Troubleshooting’’. This
flowchart, along with the other information presented in the chapter, can help
resolve problems involving more than one station or circuit pack. See also
‘‘Maintenance of the Packet Bus’’ on page 4-87 for maintenance
procedures.
!
WARNING:
If a significant packet-bus failure occurs, errors and alarms may not be
logged as expected for BRI-PORT/ABRI-POR/ATT-PORT/ LGATE-PT/
ATTE-PT. Conditions under which this occurs are detailed in ‘‘Maintenance
of the Packet Bus’’ on page 4-87 of Chapter 4, ‘‘Alarms, Errors, and
Troubleshooting’’.
MOs Name (in
Alarm Log) Alarm Level Initial Command to Run
1
1. UU is the universal cabinet number (164 for ATM PNC, 144 for CSS PNC). C is the carrier designation (A, B,
C, D, or E). SS is the number of the slot where the circuit pack resides (0121). pp is the 2-digit port number
(01, 02,...).
Full Name of MO
BRI-PORT MINOR test port PCSSpp l ISDN-BRI port
BRI-PORT WARNING test port PCSSpp sh ISDN-BRI port
ABRI-PORT MAJOR
2
,
3
2. The alarm level for ASAI and Avaya adjunct ports may be administered using the set options command. The
alarm level can be set independently for on- and off-board alarms to WARNING, MINOR, or MAJOR for every
ASAI and Avaya adjunct port in the system.
3. All alarming for an ASAI and Avaya adjunct and OFF-BOARD alarming for an ASAI or Avaya port is disabled if
the ASAI or Avaya adjunct asks the switch to suspend maintenance. When this occurs, an error and a
WARNING alarm is logged against the ASAI or Avaya adjunct. The Hardware Error and Alarm Logs should be
checked to see if the adjunct has disabled alarming.
test port PCSSpp l ASAI ISDN-BRI port
ABRI-PORT WARNING
2
,
3
test port PCSSpp l ASAI ISDN-BRI port
ATT-PORT MAJOR
2
,
3
test port PCSSpp l Avaya Adjunct ISDN-BRI
port
ATT-PORT WARNING
2
,
3
test port PCSSpp l Avaya Adjunct ISDN-BRI
port
LGATE-PT MAJOR
2
,
3
test port PCSSpp l Ethernet ASAI port
LGATE-PT WARNING
2
,
3
test port PCSSpp l Ethernet ASAI port
ATTE-PT MAJOR
2
,
3
test port PCSSpp l Ethernet Avaya Adjunct
port
ATTE-PT WARNING
2
,
3
test port PCSSpp l Ethernet Avaya Adjunct
port