EasyManua.ls Logo

Avaya S8700 - Test Cdr-Link

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
test cdr-link
Issue 1 May 2002
7-421555-233-143
test cdr-link
The test cdr-link command validates that a call detail recording link has been
administered and established. The test defaults to
short.
Parameters
For more information, see the following sections: ‘‘Common Input Parameters’’
and ‘‘Common Output Fields’’.
test cdr-link primary | secondary
[short | long] [repeat-number | clear] [schedule]
[primary | secondary] A system may have up to two CDR links: a primary that is normally
used and a secondary that serves as a backup in case the primary fails.
This qualifier specifies which link to test. Primary is the default.