Maintenance-Object Repair Procedures
555-233-143
8-1620 Issue 1 May 2002
TIE-BD (Tie Trunk Circuit Pack)
See ‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872 for circuit-pack level
errors. See also ‘‘TIE-TRK (Analog Tie Trunk)’’ on page 8-1638 for related trunk
information.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial SAT Command To
Run
1
1. UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
pp is the 2-digit port number (01, 02,...).
Full Name of MO
TIE-BD MINOR test board UUCSS sh Tie Trunk Circuit Pack
TIE-BD WARNNG test board UUCSS sh Tie Trunk Circuit Pack