Loading...
AXA12-BD/ADX8D-BD/AXD12-BD (AUDIX Circuit
Packs)
Issue 1 May 2002
8-319555-233-143
AXA12-BD/ADX8D-BD/AXD12-BD
(AUDIX Circuit Packs)
The TN568 is an EMBEDDED AUDIX circuit pack that occupies 2 slots in a port
carrier. The tests below apply only to switch-side maintenance, which tests a
circuit packs components related to the TDM-bus interface. The AUDIX system
has an extensive maintenance strategy of its own that is described in
EMBEDDED AUDIX System Maintenance, 585-300-110.
AXA12-BD:
TN568 EMBEDDED AUDIX circuit packs (sometimes called Embedded AUDIX)
operating in control-link mode appear to the system as TN746 Analog Line circuit
packs with vintage greater than 50. For circuit-pack-level problems, see ‘‘XXX-BD
(Common Port Circuit Pack)’’ on page 8-1872. The maintenance strategy for
ports on the TN568 operating in control-link mode is described in ADXCL-PT.
ADX8D-BD:
TN568 EMBEDDED AUDIX circuit packs operating in 8-port digital mode appear
to the system as TN754 Digital Line circuit packs with vintage greater than 50.
For circuit-pack-level problems, see ‘‘XXX-BD (Common Port Circuit Pack)’’ on
page 8-1872. The maintenance strategy for ports on the TN568 operating in
8-port digital mode is described in ADXDP-PT.
ADX12-BD:
The ADX12-BD MO represents a TN568 EMBEDDED AUDIX circuit pack
operating in 12-port digital (DP) mode. TN568 EMBEDDED AUDIX circuit packs
operating in 12-port digital mode appear to the system as TN2181 Digital Line
circuit packs with vintage greater than 50. For circuit-pack-level problems, see
‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872. Port-level problems are
covered by ADX12D-PT.
MOs Name (in
Alarm Log) Alarm Level Initial Command to Run Full Name of MO
AXA12-BD MINOR test board UUCSS
1
sh
1. UU is the universal cabinet number (164 for ATM PNC, 144 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides
(01 to 21).
AUDIX circuit pack
AXA12-BD WARNING test board UUCSS sh AUDIX circuit pack
ADX8D-BD MINOR test board UUCSS sh AUDIX circuit pack
ADX8D-BD WARNING test board UUCSS sh AUDIX circuit pack
AXD12-BD MINOR test board UUCSS sh AUDIX circuit pack
AXD12-BD WARNING test board UUCSS sh AUDIX circuit pack