Maintenance-Object Repair Procedures
555-233-143
8-318 Issue 1 May 2002
Diagnostic Test—Auxiliary Trunk Test (#114)
The system software sends a message to the on-board microprocessor to operate
a relay in the port circuit. If ground is detected, the test passes.
Table 8-139. Test #114 Diagnostic Test—Auxiliary Trunk Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle.
2. Retry the command at 1-minute intervals up to 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle.
2. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL This test failed to detect ground.
1. Try the test once more.
2. If the test fails again, replace the circuit pack.
PASS This test passed. Ground was detected.
Continued on next page