AUX-TRK (Auxiliary Trunk)
Issue 1 May 2002
8-317555-233-143
Audit Update Test (#36)
This test will send updates of the auxiliary trunk port translation for every port on
the Auxiliary Trunk circuit pack that has been translated. The update is
non-disruptive and guards against possible corruption of translation data
contained on the circuit pack. No response message is expected from the circuit
pack once it receives translation updates. The port translation data includes:
Trunk type
DTMF time slot
Termination R/RC
Gain, high/low
End-to-end signaling, tone, and pause duration
Trunk state, idle/active/unavailable
Companding mode (A-law or mu-law)
Table 8-138. Test #36 Audit Update Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1006 ABORT Port is in out-of-service state as a result of being busied out. This audit cannot
be run.
1. Retry the command once the port is in service (Release port UUCSSpp
command has been run).
2100 ABORT Could not allocate the necessary system resources to run this test.
FAIL Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS This test passed. Translation information was successfully updated on the
circuit pack.