Maintenance-Object Repair Procedures
555-233-143
8-726 Issue 1 May 2002
E-DIG-STA (Emulated Digital Line)
There are 4 tests in the Emulated Digital Line station maintenance test sequence
and only one test path in the test sequence. Once the test sequence begins,
every test in the test sequence is executed.
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack
and the hardware connected to those ports for lines administered as a digital
station. These include stations with an emulated digital voice terminal and
stations with an emulated digital voice terminal and a linked data module.
Stand-alone data modules and data adaptors in stand-alone mode are not
supported by the TN800 circuit pack. Circuit pack maintenance is covered by
E-DIG-BD.
MOs Name (in
Alarm Log) Alarm Level
Initial SAT Command to
Run
1
(a) (b)
1. Where UU is the universal cabinet number (164 for ATM PNC, 144 for CSS PNC); C is the
carrier designation (A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit
pack resides (1 21); and pp is the 2-digit port number (01, 02, 03, ...).
Full Name of MO
E-DIG-STA MINOR test port UUCSSpp l Emulated Digital St.
E-DIG-STA WARNING test port UUCSSpp sh Emulated Digital St.