Maintenance-Object Repair Procedures
555-233-143
8-1334 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. Error type 1—These are in-line errors and can only be resolved over time.
■ 40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may
ring simultaneously. A 5th incoming call will cause an inline error
from the board.
■ 40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure
in the terminal equipment or the type of terminal has a low ringer
impedance. Call the terminal equipment and verify that the terminal
rings. If the terminal does not ring, then replace it. Otherwise, issue
the test port UUCSSpp command, and follow the procedure for
Test #48.
■ 40977 indicates that terminal equipment was not connected when
ringing was attempted. Run the short test via the test port
UUCSSpp command, and follow the procedure for the results of
Test #48.
b. Error type 15—A software audit error that does not indicate hardware
malfunction. Run the short test sequence, and investigate associated
errors.
Table 8-539. Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) 40960,
40975,
40977
none
15 (b) Any Audits and Updates
test (#36)
18 0 busyout station
extension
WARNING ON release station extension
257 (c) 40973 none
513 (d) Station Present test
(#48)
WARNING OFF test port UUCSSpp sh r 2
769 Battery Feed test (#35) MINOR
WARNING
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
ON test port UUCSSpp sh r 2
2817 (e) Hyperactive MINOR OFF