ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 1 May 2002
8-41555-233-143
FAIL The reflective loop-around test failed. This causes noisy or unreliable
connections or other users calling this port may hear an echo.
1. Replace the circuit pack.
PASS The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investigated by using
other port tests, by examining station wiring, or by examining the station.
Table 8-15. Test #161 Loop-Around Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page