ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 May 2002
8-301555-233-143
18,
None
FAIL ATM-TRK circuit pack writing on unauthorized TDM time slots. The error code
indicates the number of TALKER DSPs that are at fault. These DSPs cannot
be used again until this test of the ATM DSP test (#1293) tells the circuit pack
to use them again.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the failure persists, replace the circuit pack.
1-8 PASS ATM-TRK circuit pack not talking to un-authorized time slots on the TDM bus.
The error code indicates the number of TALKER DSPs tested.
Table 8-132. ATM Crosstalk Test (#1298) Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page