Maintenance-Object Repair Procedures
555-233-143
8-304 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 18 indicates that the ATM WSP has been busied out with the
busyout atm wsp command. To resolve this error, check for any other
errors that would require that the WSP be made maintenance busy. Clear
every related alarm. After every related alarm is clear, or if there are no
other alarms, release the ATM circuit pack using the release atm wsp
command.
b. Error Type: 257 indicates that the WSP has become active. When a
WSP takes over, the error becomes active, and causes an alarm condition.
This error is not applicable for the main server. Use the following
procedures to return the system to normal operation:
1. Run status atm wsp on the active WSP to verify that the main
server or a higher-priority WSP that you want to be in control is up.
2. If the main server or the higher-priority WSP is up, then run reset
system 2. The active WSP should relinquish control.
3. Wait a few minutes, and run list sys-link on the main server or
higher-priority WSP to verify that the EAL and ACL system links are
up.
Table 8-133. ATM-WSP Error Log Entries
Error
Type
Aux
Data Associated Test
1
1. There are no system technician-demanded Tests associated with this MO. The tests listed in this column are
tests run by system software.
Alarm
Level
On/Off
Board Test to Clear Value
00Any Any
18 (a) MO busied out release atm wsp
257 (b) Active WSP (#1401) MAJOR OFF reset system 2
513 (c) WSP Link Status (#1400) MINOR OFF
769 (d) WSP # WSP Priority Error MINOR OFF
1025 (e) WSP Error WARNING OFF