Maintenance-Object Repair Procedures
555-233-143
8-306 Issue 1 May 2002
Example: This is WSP 1. An Aux Data of 201 indicates that WSP 2
probed this WSP, and it has a different address in the probe message than
WSP 1 has for WSP 2.
1. On WSP X, use the display atm wsp X command to determine its
address.
2. On this WSP, use the change atm wsp X command to change the
address of WSP X, if they do not match.
3. If the addresses do match, then the ATM switch has a different
address administered for WSP X, even though each WSP is
consistent.
System Technician-Demanded Tests:
Descriptions and Error Codes
There are no system technician-demanded tests associated with this MO.
Table 8-134. Error type 1025 - Aux Data error codes for YY
YY Meaning
1 The probing WSP (XX value in Aux Data) contains an ATM address in its
message that does not match the translation for that ATM address on this
WSP.