Loading...
AUX-TRK (Auxiliary Trunk)
Issue 1 May 2002
8-315555-233-143
Looparound and Conference Test (#33)
This test checks the reflective loop around and conference capabilities of an
auxiliary trunk port circuit. The test uses 404-Hz, 1004-Hz, and 2804-Hz tones.
Each tone is separately transmitted through the loop and checked. All of these
tests are performed on-board.
Table 8-137. Test #33 Looparound and Conference Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle.
2. Retry the command at 1-minute intervals up to 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle.
2. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7 FAIL The conference capabilities of the port failed.
1. If no service problems exist on the port, continue to use the port until the
circuit pack can be replaced.