Maintenance-Object Repair Procedures
555-233-143
8-334 Issue 1 May 2002
Notes:
a. Error Type 1 This error occurs when the Level 1 Status Inquiry fails or
when the BRI circuit pack detects that Level 1 has been deactivated on the
port. The aux data field contains one of the following values:
blank This indicates that the Level 1 Status Inquiry failed.
32773 This is a message from the BRI-LINE circuit pack indicating
Level 1 has been deactivated.
Refer to the repair procedures for Test #621.
b. Error Type 130 This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
replace or reinsert the circuit pack.
c. Error Type 257 This error occurs when the EPF Status Inquiry fails due
to an overcurrent condition or when the BRI-LINE circuit pack detects that
the EPF is in an over current condition. The aux data field contains one of
the following values:
blank This indicates that the EPF Status Inquiry failed due to an
overcurrent condition.
40988 This indicates that the BRI-LINE circuit pack has detected
an overcurrent condition and has turned the EPF off.
Execute the short test sequence, and see the repair procedures for
Test #622.
3846(n) TEI None
3847(o) 0 None
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate tests
description, and follow its recommended procedures.
2. Major and Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
Table 8-142. ISDN-BRI Port Error Log Entries Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
BRI-PORT
Alarm Level
ABRI-PORT
ATT-PORT
LGATE-PT
ATTE-PT
On/
Off
Board
Test to Clear
Va lue
Continued on next page