Maintenance-Object Repair Procedures
555-233-143
8-344 Issue 1 May 2002
2000 ABORT Response to the test was not received from the BRI-LINE circuit pack within the
allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the other
ports are idle. Reset the circuit pack by issuing the busyout board PCSS
and the reset board PCSS commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error.
2100 ABORT Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1, 2 FAIL As stated previously, this test runs a TDM Loop Around test on each B channel.
This indicates that the loop around failed on one of the channels. Error Code 1
indicates that the TDM Loop Around test failed on B1. Error Code 2 indicates
that the TDM Loop Around test failed on B2.
7, 8 FAIL As stated previously, this test runs a Conference Circuit test on each
B channel. A failure here indicates that one of these conference tests failed;
Error Code 7 means that the test failed on B1; Error Code 8 means that the test
failed on B2.
1. If the test fails repeatedly, attempt to reset the circuit pack if the other ports
on the circuit pack are idle. Reset the circuit pack by issuing the busyout
board PCSS and the reset board PCSS commands.
2. If the test fails again, replace the circuit pack.
PASS The BRI Port Local TDM Loop Around test has passed.
Table 8-145. Test #619 BRI Port Local TDM Loop Around — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page