BRI-SET, ASAI-ADJ, BRI-DAT
Issue 1 May 2002
8-371555-233-143
Table 8-156. Test #627 BRI Remote Loop Back
Error
Code
Tes t
Result Description / Recommendation
1000 ABORT Could not seize the endpoint or B channels for test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1005 ABORT The endpoint’s MIMs Supported field is administered to “no.”
1. Use the change station extension command to change parameter only if
the endpoint documentation reflects support for ISDN-BRI Management
and Maintenance Procedures.
1113 ABORT The signaling link between the switch and the endpoint is down.
1. Use the test port PCSSpp long command to clear any errors that prevent
establishment of the signaling link.
2. Examine the results of the Signaling Link Status test (#626) that is run as
part of this command. If this test aborts or fails, follow the repair procedure
for Test #626.
3. If the XID test (#628) continues to abort, escalate the problem.
1139 ABORT The EPN’s packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute the test port long PCSSpp command,
and review the results of the BRI Port Local LAN Loop Around test (#618)
to verify the repair.
1141 ABORT The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack) Maintenance
documentation.
2. If step 1 does not resolve the problem, escalate to the next tier.