EasyManua.ls Logo

Avaya S8700 - Page 110

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarms, Errors, and Troubleshooting
555-233-143
4-36 Issue 1 May 2002
Figure 4-12. Screen output for display circuit-packs 2
4. Enter display atm pnc port network on the S8700 Multi-Connect SAT.
This display tells you the ATM addresses that have been administered for
each TN230X. Verify that each ATM address (the concatenation of the five
displayed hexadecimal fields) is correct and match those administered in
the A500. See ‘‘A500 Administration’’ on page 4-39 for more information.
Administered with hard coded PNNI routes
If the port networks are addressed using hard coded PNNI routes in the
A500, the display looks like Figure 4-13 (pnc 1) and Figure 4-14 (pnc 2).
display circuit-packs 2
CIRCUIT PACKS
Cabinet: 2 Carrier: A
Cabinet Layout: single-carrier-stack Carrier Type: expansion-control
Slot Code Sfx Name Slot Code Sfx Name
11: TN746 B ANALOG LINE
01: TN2305 ATM PNC EI 12:
02: 13:
03: 14:
04: 15:
05: 16:
06: 17: TN754 C DIGITAL LINE
07:
08:
09: TN767 E DS1 INTERFACE
10: TN754 B DIGITAL LINE
’#’ indicates circuit pack conflict.