EasyManua.ls Logo

Avaya S8700 - Page 1116

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance-Object Repair Procedures
555-233-143
8-394 Issue 1 May 2002
AC-Powered Cabinets
AC Power-Distribution Unit and Battery
Charger (J58890CE-2)
Figure 8-15 on page 8-395 shows an AC power-distribution unit (List 9 or List 10).
This unit sits at the bottom of some multicarrier cabinets.
Carrier Port Power Supplies Multicarrier Cabinets
Code
System
Power Output (VDC) Location
631DA AC +5 Left side
631DB AC -48/-5 Right side
644A DC +5 Left side
645B DC -48/-5 Right Side
TN755B 165 Slots 17 and 18
631WA/AR AC +5 Left side
631WB/BR AC -48 Right side
TN736 AC -5 Used with 631
TN752 AC 165/-5 WA/WB or AR/AB
649A AC -48 at 10 Amps
+5 VDC and -5
VDC at 6 Amps
Right side on control and port
carriers. Left and right side on switch
node carriers.