Maintenance-Object Repair Procedures
555-233-143
8-404 Issue 1 May 2002
Error Log Entries and Test to Clear Values
!
WARNING:
The OLS Recycle test (#126) is destructive. For more information, see
‘‘OLS Recycle Test (#126)’’.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. For example,
by clearing error codes associated with the Battery & Battery Charger Query test
(#5), you may also clear errors generated from other tests in the testing
sequence.
Table 8-163. Carrier Port Power Supply Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1
1
1. Run the OLS Query test (#127) first using the test environment UU r 2 command. Then, if a carrier must be
recycled to clear the CARR-POW alarm, use the recycle carrier UUC command to run the OLS Recycle test
(#126). The OLS Recycle test (#126) is not included in either the long or short test sequences.
0 or 1 OLS Query test (#127) MAJOR ON test environment UU r 2
recycle carrier UUC
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
Battery & Battery Charger Query test (#5) (a) X X ND
AC Power Query test (#78) (b) X X ND
OLS Query test (carrier E) (#127) X X ND
OLS Query test (carrier D) (#127) X X ND
OLS Query test (carrier A) (#127) X X ND
OLS Query test (carrier B) (#127) X X ND
OLS Query test (carrier C) (#127) X X ND
OLS Recycle Carrier test (#126) D
Emergency Transfer Query test (#124) (c) X X ND
Cabinet Temperature Query test (#122) (d) X X ND
External Alarm Lead Query test (#120) (e) X X ND
Analog Ring Generator Initialization test (#117) (f) X X ND
Analog Ring Generator Query test (#118) (f) X X ND