CARR-POW (Carrier Power Supply)
Issue 1 May 2002
8-407555-233-143
Off-Line Switcher (OLS) Query Test (#127)
This test queries the the EPNs Maintenance for the status of the pair of OLSs in
the specified carrier. If both OLSs are on and functioning, then the test passes. If
both are not on and functioning, it fails.
Table 8-165. Test #127 OLS Query Test
Error
Code
Tes t
Result Description / Recommendation
1000 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to ABORT with error code 2000, check for system
powering problems with the EPNs A carrier. Resolve every AC-POWER
and CARR-POW alarm in a multicarrier-cabinet system or DC-POWER
alarm in a single-carrier cabinet system. Then, repeat the test.
3. If the test continues to ABORT with a 2000 error code, resolve any errors
against the EPNs MAINT (Maintenance circuit pack). Then, repeat the
test.
2029,
2500
ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
FAIL AC-POWERED SYSTEMS
There is a problem with one or both OLSs on the tested carrier.
1. For each OLS that has every status LED OFF, check the AC input to the
OLS at the OLS outlet. If there is no AC, then check the appropriate fuses
for the affected OLS. Replace open fuses. If the fuses open again or AC
does not show up at the OLS outlet, then there is probably a power wiring
problem in the cabinet.
2. At this point, AC should be present at the OLS outlet. Use the recycle
carrier UUC command (where UUC is the appropriate cabinet and carrier)
in an attempt to bring back the OLSs for this carrier. If the test passes, the
trouble is cleared. If the test does not pass, one OLS or both, in the tested
carrier is defective. If only one OLS is defective, then the status LEDs on
the healthy OLS will light green for a moment. When the recycle test
determines that both OLSs are defective, the software will turn off power to
both the good and defective OLSs. This will cause the status LED(s) on
the good OLS to light red.
3. Unplug both OLSs, and wait approximately 1-minute to allow the OLSs to
cool down. Plug in the OLSs. If either OLS is operating properly (the
status LEDs show green), then replace the defective OLS(s). See OLS
Replacement Procedures in this section.