Maintenance-Object Repair Procedures
555-233-143
8-416 Issue 1 May 2002
n. Error Type 2817-2819: Congestion Query test (#600) failed.
The Error Types correspond to the descriptions:
1. Refer to Congestion Query test (#600) for Abort and Fail 3601s.
o. Error Type 3073: RSCL (Remote Socket Control Link) or Link Status test
(#601) failed. This failure may be due to:
This circuit pack
The packet bus
The Packet Interface circuit pack.
p. Error Type 3330: Critical failure in packet-bus interface.
Below, Error Types correspond to descriptions.
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
2817 All buffers exhausted.
2819 Utilized buffers exceed threshold.
If: Then:
Active buffers exceed threshold C-LAN enters congested state.
If: Then:
RSCL disconnects at link level Link fails
Link cannot be reconnected quickly Switch raises MINOR alarm
If the switch detects: Then it:
1 error, Resets circuit pack.
2 errors in 15 minutes, Raises MINOR alarm.