CO-DS1 (DS1 CO Trunk)
Issue 1 May 2002
8-441555-233-143
1004 ABORT The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1020 ABORT The test did not run due to a previously existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the already existing error.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053 ABORT At least one of the following errors was found on the DS1 circuit pack: Loss of
signal (1281), Blue alarm (1793), Red alarm (2049), Yellow alarm (2305), or
Hyperactivity (1537).
1. Look for the previous error types in the Hardware Error Log, and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
FAIL The NPE of the tested port was found to be transmitting in error. This will
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and examining station,
trunk, or external wiring.
Table 8-179. Test #6 NPE Crosstalk Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page