Maintenance-Object Repair Procedures
555-233-143
8-468 Issue 1 May 2002
Looparound and Conference Circuit Test (#33)
This test checks the reflective loop-around and conference capabilities of a CO
port circuit. The test uses 404-Hz, 1004-Hz, and 2804-Hz tones. Each tone is
transmitted separately through the loop and checked.
Table 8-188. Test #33 Looparound and Conference Circuit Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
7 ABORT Conference Circuit test aborted.
129 ABORT The 404-Hz reflective loop-around test aborted. Response to the test request
was not received within the allowable time period.
131 The 1004-Hz reflective loop-around test aborted. Response to the test request
was not received within the allowable time period.
133 The 2804-Hz reflective loop-around test aborted. Response to the test request
was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle before testing.
2. If the port status is active but the port is idle (no calls), check the error log
for error type 769 (see the error log table for a description of this error and
required actions). The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
Continued on next page